An access control system decides electronically who may enter a building, floor or room, and when, and records every passage. Unlike a mechanical key, a lost card can be cancelled immediately and permissions can be changed centrally.
Its main components are the credential (card, tag, mobile credential, PIN or biometric feature), the reader, a controller that makes the decision, an electric lock, a door-position sensor and management software. Higher-security doors may require more than one factor, for example a card plus a PIN. Turnstiles, interlocking mantraps and vehicle barriers can be linked into the same system. Events such as a door forced open or held open too long are passed as alarms to the monitoring centre.
Electric locks on escape routes must be chosen so they do not conflict with fire and life safety, for example by releasing automatically on a fire alarm, in line with the applicable fire regulations. In Turkey, access logs are personal data and the Personal Data Protection Law (KVKK) applies. In its principle decision on biometric time-keeping, the Personal Data Protection Board listed encrypted cards, PIN systems and RFID/NFC cards among less intrusive alternatives to biometrics.
Points to watch
- Grant permissions on a least-privilege basis.
- Set up a process to cancel leavers’ credentials on their last day.
- Have the lock type on escape doors checked against fire-safety requirements.
- Brief staff on the risk of tailgating.