A perimeter intrusion detection system (PIDS) is a set of sensors that detects unauthorised crossing, or attempted crossing, of a site’s outer boundary: a fence, wall or open-ground line. Its purpose is to detect an intrusion as early as possible, before an intruder reaches buildings, to buy time for a response.
Main technologies include fence-mounted vibration or fibre-optic sensors, buried pressure or field sensors, microwave and infrared barriers that form an invisible zone between two points, radar scanning open areas, and video analytics, often on thermal cameras. Each technology has its own false-alarm profile in relation to terrain, climate, vegetation and wildlife. Two different technologies are therefore often combined, and alarms are verified with camera images. The indoor alarm standard EN 50131-1 excludes exterior systems, so perimeter systems need their own assessment.
An effective PIDS depends on three elements working together: detection, assessment (quickly establishing whether an alarm is real) and response. Early detection has little value unless the response can arrive before an intruder reaches the target.
Points to watch
- Select technology for the terrain and climate, using site trials.
- Make sure every alarm can be checked quickly on camera.
- Schedule vegetation and fence maintenance.
- Align detection zones with the response plan.