Can an IP camera be hacked? Any networked device can be misused if it keeps factory settings, misses updates or is reachable from places it should not be, and cameras, recorders and access controllers are no exception. The good news is that a short set of defensive basics substantially reduces everyday exposure: know every device you own, remove default passwords, keep software supported and updated, separate the security network, control remote access, and watch the logs. This article sets out that baseline for IT and facilities teams, without going into attack methods.
It complements, rather than repeats, the governance view of physical and cyber convergence. Here the focus is practical: what to ask for, what to check, and who does what.
Security devices are IT assets
Cameras, recorders, video management servers, door controllers and alarm communicators run software, hold credentials and talk over the network. They belong in the same asset and risk process as laptops and servers, ideally under the scope of your ISO/IEC 27001 information security management system if you have one.
A useful reference for what such devices should be able to do is NIST IR 8259A, the IoT Device Cybersecurity Capability Core Baseline (May 2020). It names six device capabilities: device identification, device configuration (changeable only by authorised entities), data protection, logical access to interfaces (restricting local and network interfaces to authorised entities), software update (by authorised entities through a secure, configurable mechanism) and cybersecurity state awareness (the device can report on its security state). Turn these six into procurement questions and you have the core of a technical requirement for any IP camera or controller.
A second reference is ETSI EN 303 645, whose current version V3.1.3 dates from September 2024. It is written for consumer devices, and its scope list explicitly includes smart cameras and connected alarm systems. Its thirteen headings, from “no universal default passwords” and “keep software updated” to “minimize exposed attack surfaces” and “make systems resilient to outages”, make a clear checklist for enterprise buyers as well.
1. Build and keep an inventory
You cannot protect what you cannot see. For every device record its location, function, network address, software version, owner and the supplier responsible for it. NIST’s first capability, unique logical and physical identification, exists for exactly this reason. Make the inventory a deliverable at handover and a duty in the maintenance contract, and reconcile it at least whenever devices are added, moved or replaced. Devices that nobody remembers, such as an old recorder in a cupboard, are among the weakest points in any network.
2. Identity and passwords
The first provision in ETSI EN 303 645 is that no universal default passwords should be used: where passwords are used, each must be unique per device or defined by the user. On site, translate this into simple rules:
- No factory password survives commissioning, on any device or software account.
- Every operator and administrator has a personal account; shared “admin” logins are removed.
- Rights follow roles: an operator who views live video does not need export or configuration rights.
- Stronger authentication is used for remote and administrative access where the system supports it.
- Administrator credentials are handed over under control at the end of the project and changed when staff or suppliers change.
3. Updates and the support period
ETSI’s third heading is to keep software updated, and the standard defines a “defined support period”: the minimum time, expressed as a period or an end date, during which a manufacturer provides security updates. Ask for this before you buy. A device whose support ends soon after installation will be a long-term problem however good it looks today. In operations, agree who checks for updates, who tests them, who approves installation and how the work is recorded. NIST’s software-update capability adds that updates should only be possible for authorised parties through a secure mechanism.
4. Network separation and remote access
As a general principle, security systems should live in their own network segment, separated from office IT and guest networks, with only the connections they actually need. Device management interfaces should not be reachable directly from the internet. When a supplier or a central monitoring room needs remote access, it should pass through a channel the organisation controls, be granted per person, be logged, and be removed when no longer needed. Unused services on devices should be switched off, in line with ETSI’s “minimize exposed attack surfaces”, and communication between devices and software should be encrypted where supported.
The detailed design of these controls belongs to your IT and network team. The security manager’s job is to make sure the requirement is written into the specification and checked at handover.
5. Logs and monitoring: who watches what
NIST’s last capability, cybersecurity state awareness, means the device can report its security-relevant state. That is only useful if someone looks. Agree a shared routine between the security control room and IT:
- The control room sees “camera offline”, “recording failed” or “door controller not responding” events and treats them as security events, sending an officer to check the device and the area when needed.
- IT or the security operations team reviews login failures, configuration changes and unusual traffic from the security network.
- Both sides know whom to call, and the event is recorded in one place.
Technology records the anomaly; trained people decide whether it is a fault, a mistake or an incident, and respond. Write this split into post orders as well as into IT procedures.
Supply chain and maintenance questions
Some of the risk arrives through the supply chain and the maintenance relationship rather than through the device itself. Ask suppliers and maintenance providers:
- Does the manufacturer publish a way to report vulnerabilities? (ETSI’s second heading.)
- What is the defined support period for each device and software component?
- How will updates be delivered, tested and documented under the maintenance contract?
- Who on the supplier side holds remote access, and how is it controlled and revoked?
- Will the inventory, configuration backups and administrator credentials be handed over in full?
When something goes wrong: report it
If you suspect a cyber incident affecting security systems in Turkey, isolate the affected part according to your incident plan, preserve logs, inform management and your IT security team, and report to the National Cyber Incident Response Centre (USOM). USOM’s page announces the establishment of the Presidency of Cyber Security and states that USOM’s services, including cyber incident reporting, will continue to be published via siberguvenlik.gov.tr. Where personal data such as camera footage or access logs may be involved, also take legal advice on your notification duties. In the meantime, keep the physical side covered: if cameras or door controllers are taken offline, add patrols or fixed posts until the system is trusted again.
Baseline checklist
- Complete, current device inventory with owner and software version.
- No default or shared passwords; personal, role-based accounts.
- Defined support period known for every device; update routine agreed.
- Separate network segment; no management interfaces exposed to the internet.
- Remote access through a controlled, logged channel only.
- Offline and tamper events monitored by the control room; logs reviewed by IT.
- Incident plan names USOM reporting and physical fallback measures.
How a professional security partner helps
Titan Savunma is an Ankara-based private security company with a Ministry of Interior operating licence under Law 5188 and ISO 9001, 14001, 45001, 22301 and 28000 certificates, working with international companies in English and Turkish. We do not sell or configure technology; we plan guarding together with your technology, so that offline cameras, failed doors and suspected incidents have a clear monitoring, verification and response plan on the ground. A good first step is our free security risk assessment; see also our data centre physical security page.