Industry & Logistics

Major-Hazard (Seveso) Sites in Turkey: Security Duties

Turkey's major industrial accident regulation explained: tiers, safety report, internal emergency plan, and where security, chemical security and AFAD fit in.

Titan SavunmaOriginal Article: Updated: Approximately 8 min read
A security officer using a tablet at night in front of a green storage dome.
In This Article

This article is general information, not legal advice.

Turkey transposed the EU's Seveso III Directive through the Regulation on the Prevention and Mitigation of Major Industrial Accidents (Büyük Endüstriyel Kazaların Önlenmesi ve Etkilerinin Azaltılması Hakkında Yönetmelik), published in the Official Gazette No. 30702 on 2 March 2019. If your plant stores or processes dangerous substances above the regulation's thresholds, it is a lower-tier or upper-tier establishment with duties ranging from a major accident prevention policy to a full safety report and an internal emergency plan.

The regulation is about accidents, not crime. Its articles do not mention sabotage or unauthorised access. Security nevertheless sits inside the safety system in three places: the hazard scenarios the operator must consider, the emergency arrangements required by Turkish occupational safety rules, and the coordination with authorities when something goes wrong. This article explains the regulation in plain terms and shows where a security function, in-house or contracted, should plug in. Article numbers below follow the current text on mevzuat.gov.tr.

Scope and tiers

The regulation applies to establishments where dangerous substances are present in quantities at or above the thresholds in its Annex 1, including quantities that could be generated if control of a process is lost. As in the Seveso III Directive, there are two tiers:

  • Lower-tier establishment (alt seviyeli kuruluş): quantities at or above the Annex 1 column 2 threshold but below column 3.
  • Upper-tier establishment (üst seviyeli kuruluş): quantities at or above the column 3 threshold.

Some activities are excluded, among them military establishments, transport of dangerous substances outside the establishment, pipelines outside the establishment, and mineral extraction in mines and quarries. Operators declare their tier through the environment ministry's notification system before operation and update the notification after relevant changes.

Core documents and where security fits

DocumentWhoSecurity input
Major accident scenario document (Art. 8)Lower and upper tierInternal and external hazards to the hazardous equipment; whether deliberate interference is considered alongside accidental causes
Major accident prevention policy (Art. 10)Lower tierSafety management system elements on organisation, operational control and emergencies
Safety report (Art. 11)Upper tierDescription of the safety management system, including control of access to hazardous areas
Internal emergency plan (Art. 13 and 14)Upper tierGate control, roll-call, guiding emergency services, protecting the scene

The scenario document starts by identifying hazardous equipment and its internal and external hazards before building accident scenarios. The Seveso III Directive likewise asks for causes internal or external to the installation, giving domino effects and natural events such as earthquakes and floods as examples. Neither text lists malicious acts. A careful operator can still record, at planning level, whether theft, tampering or an attack on a tank farm could start one of the identified scenarios, and which barriers address that. This keeps safety and security registers consistent without putting sensitive detail into documents that are widely circulated.

The safety report must describe the safety management system. The directive's list of system elements covers organisation and personnel, identification and evaluation of major hazards, operational control, management of change, planning for emergencies, monitoring performance, and audit and review. Access control to process units, contractor control and the gatehouse role in emergencies fit naturally under operational control and emergency planning.

Internal emergency plan: what security does on the day

For upper-tier sites, the operator prepares an internal emergency plan, reviews it at intervals not exceeding three years, exercises it and makes sure emergency services take part adequately. In a major accident, or an uncontrolled event likely to lead to one, the operator activates the plan immediately and informs the provincial disaster and emergency directorate, the local arm of the Disaster and Emergency Management Authority (AFAD). If the internal plan is not enough, the provincial directorate coordinates the response under the provincial disaster response plan.

Separately, Turkish occupational safety rules apply to every workplace. The Ministry of Labour's 2021 programmed inspection report on major-hazard workplaces quotes the Regulation on Emergency Situations at Workplaces: the employer must consider, among other things, the possibility of fire and explosion, releases of hazardous substances, natural disasters and sabotage when identifying emergencies, and must set up emergency teams that include firefighting, rescue, protection and first-aid teams. Sabotage is therefore already a named emergency in Turkish workplace law, even though the major-accident regulation does not use the word.

Typical security tasks in the plan:

  • Close or control gates instantly, stop non-essential entry and keep a lane clear for fire, ambulance and law-enforcement vehicles.
  • Run the visitor and contractor roll-call from gate records so that muster counts are accurate.
  • Meet and guide the fire service and the 112 emergency teams to the right access point.
  • Keep the public and media away from the boundary and protect the scene for later investigation.
  • Log times and decisions; after a major accident the operator must notify the governorship (valilik) and several directorates immediately and file a report later.

Chemical security good practice

The Organisation for the Prohibition of Chemical Weapons (OPCW) published Indicative Guidelines for Chemical Safety and Security in Small and Medium-sized Enterprises in 2021. They define chemical security as policies and practices to prevent malicious or illicit use of chemicals and to mitigate the impact if it happens, and contrast the two kinds of barrier: safety barriers protect people from chemicals, security barriers protect chemicals from people.

The guidelines also make a point that matters for every Seveso site: safety and security usually reinforce each other but sometimes conflict. Access control helps both, because it keeps untrained and unauthorised people away from hazardous areas. But locking doors against theft can obstruct emergency exits, and restricting information on chemical names, quantities and locations can work against hazard communication. The guidelines advise considering safety and security requirements as a whole so that these conflicts are resolved deliberately.

Practical measures at planning level:

  • Layered access to tank farms, loading bays and stores of the most hazardous substances, with authorisation lists kept current.
  • Inventory reconciliation for substances that could be misused, so that a loss is noticed.
  • Personnel and contractor checks proportionate to role, within the Personal Data Protection Law No. 6698.
  • Emergency exits that open from inside at all times; security never achieved by chaining a safety door.
  • A review of public information: the regulation requires lower and upper-tier operators to publish information for the public online, and upper-tier sites more. Publish what the law requires, and keep operational security detail, such as patrol routes or camera coverage, out of public documents.

Coordination with AFAD, the governorship and neighbours

Major-hazard sites are rarely alone. Neighbouring plants in an organised industrial zone, residential areas and roads all fall within the possible consequence zones. A 2020 review by Güneş and Çetinyokuş in a DergiPark journal argued that land-use planning around industrial establishments, meaning safety distances and zoning near hazardous sites, was not then addressed in Turkish legislation and proposed solutions drawn from international practice. For operators this underlines the value of active coordination:

  • Share emergency contact points and gate arrangements with the provincial disaster and emergency directorate and the fire service.
  • Agree with neighbouring sites and the zone management how alarms, road closures and evacuation routes interact.
  • Invite emergency services to exercises; the regulation expects their adequate participation in internal plan tests.
  • Make sure the security team knows which authority to call for what: 112 for emergencies, the plant's emergency coordinator for internal decisions.

Inspections and common gaps

Under Article 18, inspection programmes cover upper-tier establishments at least once every two calendar years and lower-tier establishments at least once every four calendar years; unscheduled inspections can follow a major accident. The 2021 labour inspection programme reached 477 workplaces covered by the regulation in 60 provinces. Its deficiency lists include emergency plans, drills and assembly points, and missing work instructions and permits in potentially explosive atmospheres. Security-related gaps we would add to an internal pre-inspection walk: gate procedures that do not match the emergency plan, out-of-date roll-call lists, and no record of security staff taking part in drills.

About Titan Savunma

Titan Savunma is an Ankara-based private security company licensed by the Ministry of Interior under Law No. 5188, certified to ISO 9001, 14001, 45001, 22301 and 28000. We plan security for industrial sites in different provinces with a single point of contact, a written scope and regular reporting, and we align gate and emergency duties with the operator's safety documents. Read more about critical infrastructure security and industrial facility security.

Sources and Further Reading

← Back to Security BulletinBack to Top
For Your Organisation

Let’s Discuss Your Security Needs

Tell us about your operations and expectations so we can define the appropriate service scope together.

Contact

Request a Security Proposal for Your Organisation

Tell us your facility type, location and general requirements. Together, we can define a service scope that suits your organisation.

Tell Us What You Need

Fields marked * are required.

What Happens Next

  1. Initial DiscussionWe respond within 15 minutes and clarify your requirements and facility details together.
  2. Service ScopeWe assess staffing needs and the working arrangements.
  3. ProposalWe prepare our proposal for the agreed service scope.

General Directorates

Ankara · Çankaya
İstanbul · Levent

Nine regional directorates · 81 provinces

Looking for a role? Visit our careers page