Short answer: In Çanakkale, wind turbines, switchyards and the cable routes that connect them are scattered across remote, exposed countryside, often far apart. On sites like these, security is decided less by where a guard hut stands than by how quickly, and by whom, an alarm or camera event is verified. A workable arrangement has three parts: a site map showing which points a camera covers and which a patrol covers; a written verification sequence for each type of alarm (picture first, a physical check if needed, then notification); and scheduled maintenance of cameras, masts and links. Below we set out those three parts against the research evidence and Çanakkale's own climate and hazard data.
Why energy-site security is its own subject in Çanakkale
Energy is not just another sector in the province. According to the Turkish Social Security Institution's 2025 statistical yearbook, 3,728 insured employees work at 110 workplaces in electricity, gas, steam and air-conditioning supply in Çanakkale. Measured against the province's 101,633 compulsorily insured employees, the sector's share is roughly five times its share nationally (our own calculation). Energy installations therefore stand out in the province both as a notable employer and as assets that need protecting.
Many of these installations are not compact plants behind a single fence. A wind site is made up of turbine bases spread along ridges, internal tracks, collector cables, a switchyard or substation, yards holding spare parts and cable drums, and temporary work areas used by maintenance crews. Each part carries a different risk, is visible to a different degree and takes a different time to reach.
Climate is a planning input too. Turkish State Meteorological Service records for the Çanakkale station over 1929–2025 show a fastest wind of 38.7 m/s (15 February 1991) and a maximum snow depth of 63 cm (26 January 2006). Wind drives generation, but it also loads camera masts, fence panels and wireless links. The World Bank-supported ThinkHazard profile rates earthquake, wildfire and landslide hazard in the province as “high”. A security plan for a rural energy site should therefore cover early sight of fire and post-earthquake continuity as well as theft and intrusion.
What the research says
Remote, dispersed sites create a distinctive risk surface
Writing in the International Journal of Critical Infrastructure Protection, US researchers Staggs, Ferlemann and Shenoi (2017) examined a generic wind farm architecture. Their abstract notes that geographic scale, remote assets, flat control networks and insecure control protocols expose wind farms to many threats. They consider attack routes against IT systems, industrial control systems and physical assets together, and their scenarios include unauthorised turbine control, damage to turbines and the substation, and disruption of the whole farm. Judging by the abstract, the paper's weight lies on control networks and protocols, but the lesson for guarding is practical: turbine doors, control cabinets and the switchyard are physical access points, so the physical security team and the operator's information security team should work from the same asset list. The authors propose mitigation techniques and note that site-specific details are needed for a complete risk management programme.
Having a camera is not the same as seeing
In a field study published in Security Journal, Keval and Sasse (2010) interviewed 13 managers and 38 operators and observed work in 13 CCTV control rooms in and around London. The study concerns urban public-space cameras rather than energy sites, yet its findings offer lessons for remote monitoring too. In the authors' severity rating, blind spots and views blocked by trees and foliage were rated “very serious”, cameras left by the previous shift in “useless” positions “serious”, and broken camera controls “moderate”. In 6 of the 13 rooms, (analogue) camera signals dropped out temporarily in bad weather and slow repairs frustrated operators. On the ratios in the study's table, each operator was responsible for roughly 18 to 120 cameras (our calculation), and the authors describe the camera-to-operator ratio as far too high. In the 4 rooms that combined camera lists and maps in a single interactive system, operators were observed responding faster and with more confidence. The recommendations include automatic reporting of failing cameras, reviewing equipment and every camera every four to six months, and numbering cameras in geographical order.
Most alarms are not real events, so the verification sequence matters
The US Department of Justice-supported guide “False Burglar Alarms” (Sampson, 2nd edition) reports that between 94 and 98 per cent of burglar alarm calls to police turn out to be false. It cites a UK study in which user error caused about half of alarm activations. The first of the responses the guide lists is “verified response”: the monitoring centre confirms an alarm is genuine, by seeing it on site or through remote video, before calling police, and on-site checks are usually carried out by private security staff who travel to the location. The guide adds that audio-only verification is not nearly as effective as visual checks. Those findings concern US police workload, but the lesson for an energy site in Türkiye is simple: unless “what must be seen first, who goes, who is told” is written down for every alarm type, a team will either run to every alarm or, before long, take none of them seriously.
On rural sites, cameras can also spot fire early, within limits
A review in Sensors by Barmpoutis and colleagues (2020) compares ground-based, airborne and satellite optical systems for early wildfire detection. It concludes that ground-based camera systems tend to be more efficient in accuracy and response time, but because cameras sit in fixed positions their coverage is limited and obstructions add further constraints. Colour-only detection methods suffer from high false alarm rates; many researchers have turned to infrared cameras to reduce false alarms from ground-based systems, and one study cited in the review used deep learning to cut false alarms caused by clouds, sunlight reflections and fire- or smoke-coloured objects. In a province with high wildfire hazard, it makes sense to position some site cameras with smoke and flame visibility in mind and to write a verification step for “smoke alerts” as well.
Site components and the security task at each
| Component | Main risk | Camera's job | Officer's job |
|---|---|---|---|
| Switchyard / substation | Intrusion, equipment damage, unauthorised people near live equipment | Continuous view of the fence line and gate, entry record | Key and gate log, matching entrants against the operator's authorised list; never entering energised areas |
| Turbine bases and tower doors | Forced doors, vandalism, access to control cabinets | Matching door-open alarms with images | Door and lock checks on patrol, findings logged with photographs |
| Cable route and drum/stock yard | Theft, signs of digging, manholes left open | Views focused on the yard and vehicle entry | Accompanying stock counts, noting changes along the route |
| Internal tracks and barriers | Unrecorded vehicles, loads leaving site | Number-plate and vehicle images | Vehicle-paperwork-load matching, visitor log |
| Camera masts and communications cabinets | Wind, snow, power cuts, lost links | “Video loss” alarm | Checking outages on the first round, reporting faults to the operator in writing |
| Temporary maintenance work areas | Contractor traffic, forgotten equipment, open doors | Recording during works | End-of-day closing round, checking against the operator's permit-to-work list |
A five-step alarm verification sequence
- Classify: sort alarms by type: fence or door, motion detection, video loss, smoke or flame alert. Each type should have its own instruction.
- Verify by image first: the monitoring point calls up the preset view of the relevant camera and marks the recording before and after the event. If camera lists are not linked to a map in geographical order, this step takes longer.
- Check on site if needed: if the picture is not conclusive, a patrol is sent. Rules on lone working and movement at night and in bad weather should follow the operator's occupational health and safety instructions.
- Notify: the operator's shift supervisor and, where needed, police and the fire service. Who is told, in what order and with what information should be written down in advance.
- Close the record: cause, time to verify, location of the footage and outcome. False alarms that recur at the same point should be listed monthly and their source (settings, vegetation, objects moving in the wind, user error) removed.
Practical checklist
- Is there one map showing every component of the site, with each camera and alarm point marked by number?
- Is the “image first, site check second, notification third” sequence written down for each alarm type?
- Are camera fields of view checked at least twice a year against seasonal vegetation and snow build-up?
- Is video loss monitored as a separate alarm and checked in person on the next patrol?
- Are masts, junction boxes and power supplies inspected after storms?
- Do switchyard keys and gate records match the operator's authorisation list?
- Have the points needing infrared or thermal imaging (night, smoke, fog) been identified?
- Does the business continuity plan define the security team's role after an earthquake, a fire or a long communications outage?
- Are retention periods and access rights for camera footage written down?
Common mistakes
- Installing cameras without writing down who watches them and how often.
- Treating every alarm the same way, then silencing alarms once false ones pile up.
- Logging video loss as a “technical fault” rather than a security event.
- Leaving camera angles as they were on installation day, ignoring growing vegetation and changed winter views.
- Planning the switchyard and the turbines separately and forgetting the cable route and stock yard in between.
- Physical security and information security teams working from different asset lists.
- Leaving smoke alerts out of the security instructions in a province with high wildfire hazard.
Notes for Türkiye
The powers of private security officers are set out in Law No. 5188 on Private Security Services and are limited to their assigned area, so post orders for an energy site should show the boundaries of that area clearly. Intervening on live equipment is a job for the operator's authorised technical staff; the security team observes, records and reports. Camera footage and entry logs contain personal data; purpose, retention and notice should follow the rules set by the operator as data controller under Law No. 6698 on the Protection of Personal Data. In a province with high earthquake hazard, the security team's tasks in the first hours after an earthquake (closing the site, accounting for people, back-up communications) belong in the business continuity plan.
You can read about our approach in the province on our private security in Çanakkale page, and about our plan for energy facilities on our energy generation and distribution security page. To sketch the guarding points on your own site, try our security coverage planner.
Titan Savunma is an Ankara-based private security company licensed by the Ministry of Interior under Law No. 5188 and certified to ISO 9001, 14001, 45001, 22301 and 28000. We work with international companies in English and Turkish; our Çanakkale City Manager, together with our Marmara Regional Directorate and our Istanbul General Directorate, walks your site in person and puts the camera map, alarm verification sequence and patrol routine on paper with you. To arrange a site survey, please use our contact page.
Sources and Further Reading
- Staggs, J., Ferlemann, D. & Shenoi, S. — Wind farm security: attack surface, targets, scenarios and mitigation, International Journal of Critical Infrastructure Protection 17:3–14 (2017)
- Keval, H. & Sasse, M. A. — “Not the Usual Suspects”: A Study of Factors Reducing the Effectiveness of CCTV, Security Journal 23(2):134–154 (2010)
- Barmpoutis, P., Papaioannou, P., Dimitropoulos, K. & Grammalidis, N. — A Review on Early Forest Fire Detection Systems Using Optical Remote Sensing, Sensors 20(22):6442 (2020)
- Sampson, R. — False Burglar Alarms, 2nd Edition, Problem-Oriented Guides for Police No. 5, US DOJ COPS Office / Center for Problem-Oriented Policing (2011)
- Sosyal Güvenlik Kurumu — SGK İstatistik Yıllığı 2025, Bölüm 1: Sigortalı ve İşyeri İstatistikleri (Tablo 1.11)
- Meteoroloji Genel Müdürlüğü — Resmi İstatistikler: Çanakkale (1929–2025)
- GFDRR ThinkHazard! — Çanakkale hazard report (earthquake, wildfire, landslide)
- 5188 sayılı Özel Güvenlik Hizmetlerine Dair Kanun — Mevzuat Bilgi Sistemi
- 6698 sayılı Kişisel Verilerin Korunması Kanunu — Mevzuat Bilgi Sistemi