Securing a geothermal power plant in western Turkey is not the same job as securing a solar farm next door. The asset is spread across well pads, kilometres of hot pipelines and a power island, often among fig orchards, vineyards and olive groves, and the process itself can release hydrogen sulphide (H2S), a toxic gas. A good security plan therefore starts from process safety: guards must know where they may and may not go, what an H2S alarm means for them, and how to help an emergency rather than become part of it.

This guide is for owners, investors and operators of geothermal plants in Aydın, Denizli, Manisa and neighbouring provinces. It covers site layout, the occupational health and safety duties that protect the guards themselves, the relationship with farming communities, the choice between patrols and fixed posts, emergency coordination and contractor access during drilling.

This article is general information, not legal advice.

Why western Turkey, and what the site looks like

According to the Ministry of Energy and Natural Resources, around 78% of Turkey's geothermal potential areas are in Western Anatolia, and geothermal electricity generation in Turkey began in 1975 with the 0.5 MWe Kızıldere plant. The Ministry adds that Turkey's visible geothermal potential grew rapidly once the private sector joined exploration and investment after the Geothermal Resources and Natural Mineral Waters Law came into force. The result is a concentration of plants in western provinces such as Aydın, Denizli and Manisa, where international investors and lenders are also active.

A typical site has three zones with different security needs:

  • Well pads for production and reinjection wells, often scattered across agricultural land and reached by field roads. Some have wellhead cellars, which the IFC treats as confined spaces.
  • Gathering and reinjection pipelines that carry hot fluid between wells and the plant, sometimes above ground, crossing farmland and local roads.
  • The power island: separators, turbines, condensers, cooling towers, the control room, the switchyard and warehouses. This is where most people and most valuable movable equipment are concentrated.

H2S and guard safety under Law 6331

The World Bank Group EHS Guidelines for Geothermal Power Generation list geothermal gases, mainly H2S, alongside confined spaces, heat and noise as the specific occupational hazards of the sector. Exposure may occur during non-routine releases such as pipeline failures and during maintenance in confined spaces, and the significance varies with the geology of the site. Where hazardous exposure is possible, the Guidelines recommend H2S monitoring and warning systems placed on the basis of an assessment, a contingency plan for release events covering everything from evacuation to resumption of operations, personal monitors and breathing apparatus for emergency teams and high-risk workers, and a confined-space entry programme. They also note that noise can temporarily exceed 100 dBA during some drilling and steam venting.

Guards are workers too. Under Law No. 6331 on Occupational Health and Safety, their employer, the security company, must ensure their health and safety (Article 4), carry out a risk assessment (Article 10), prepare for emergencies including evacuation (Articles 11 and 12) and train them (Article 17). Article 13 gives workers facing serious and imminent danger the right to refrain from work. Because the guards work on the plant operator's site, Article 23 requires the employers sharing that work area to cooperate, coordinate risk prevention and inform each other about risks. In practice this means:

  • The plant's H2S risk map, alarm signals and muster points are shared with the security company and built into guard post orders.
  • Guards receive the plant's own gas-awareness induction, and personal gas monitors are issued where the joint risk assessment says patrol routes or posts need them.
  • Guards never enter cellars, pits or other confined spaces, including to rescue someone; their job is to raise the alarm and guide the trained team.
  • Patrol routes avoid low points where gas can collect and take account of wind direction shown on the site's windsocks.

Working alongside farming communities

Most geothermal fields in the region sit among working farms, so the security team meets neighbours every day: farmers using shared field roads, shepherds, seasonal workers, landowners of pipeline corridors. Research shows why these relationships need care. In a survey of 200 farmers in Aydın and Manisa whose land was relatively close to geothermal facilities, Öztürk and Çobanoğlu (2023) found that farmers reported significant yield and quality losses, especially for figs and vineyards, and recommended more environmentally sensitive approaches and effective self-control systems. Whatever one's view of the causes, it means a guard at a well pad may be the first company representative an unhappy farmer speaks to.

The security plan should treat this as community interface, not as a threat. Guards should be courteous, record the concern, pass it into the operator's grievance mechanism and avoid arguments about the plant's environmental performance. The World Bank Group Guidelines also recommend fences and warning signs to keep the public away from hot components and well infrastructure; explaining why a fence is there is part of the job. Agricultural seasons matter too: harvest periods bring more vehicles and workers onto shared roads, which changes patrol timing and gate traffic.

Patrols, fixed posts and the duty area

Geothermal fields usually need a mix: a fixed post at the power island entrance, where visitors, contractors and deliveries are controlled, and patrols covering well pads and pipeline corridors. Our bulletin on mobile patrol versus static guarding sets out the general decision criteria; at a geothermal site, add three local factors.

  • Legal duty area. Under Article 9 of Law No. 5188, private security officers may use their powers only during duty hours and within their duty area, which can be extended by commission decision when necessary. When well pads and pipelines are spread across third-party land, make sure the private security permit and the protection and security plan describe the areas actually patrolled.
  • Process hazards. Patrol routes and timings are agreed with the operator's health and safety team, not chosen only for coverage.
  • Detection support. Cameras and intrusion sensors at remote well pads reduce the need to send people into hazardous zones; Article 5 of Law 5188 requires a governorship qualification certificate to operate an alarm monitoring centre if alarms are watched remotely.

Emergency coordination

The emergencies that matter at a geothermal plant are mostly process events: gas releases, pipeline ruptures, fires and, during drilling, well control incidents. The security team's role is clear and limited. It raises the alarm, controls the site gates and internal roads so that emergency vehicles get in and unauthorised people stay out, helps account for people at muster points, guides external responders reached through 112, and keeps records. Article 15 of the Implementing Regulation also obliges private security officers to help search and rescue teams in fires, earthquakes and floods within their duty area.

The IFC Guidelines recommend that where community exposure to H2S is significant, emergency planning should involve community input so that warnings lead to effective responses. The security team often knows which farms and houses are nearest each well pad; that knowledge belongs in the plant's emergency plan, together with the contact details of village headmen (muhtar) and the local gendarmerie station.

Contractor access during drilling and workovers

Drilling a new well or working over an existing one turns a quiet well pad into a busy industrial site: rig crews on rotating shifts, heavy vehicles, mud and cementing contractors, wireline teams and deliveries around the clock. The security plan should change with it:

  • A named access list from the drilling contractor, refreshed at each crew change, with vehicles registered.
  • Confirmation at the gate that each person has completed the operator's site induction, without the guard becoming the safety officer.
  • Gate control at the pad entrance during heavy-load movements; traffic management on public roads is a matter for the gendarmerie, with whom the operator coordinates in advance.
  • Secure storage arrangements for tools and materials, which are attractive targets on remote pads.
  • A clear rule on who may approach the rig floor and cellar: guards do not.

Checklist for geothermal security planning

  • Site map with well pads, pipelines, power island, H2S monitor locations and muster points shared with security.
  • Joint 6331 risk assessment and coordination record between operator and security company.
  • Guard post orders covering gas alarms, confined-space prohibition and evacuation routes.
  • Permit and protection and security plan describing the real duty area.
  • Community contact log feeding the grievance mechanism.
  • Drilling-phase access plan with contractor lists and induction checks.
  • Emergency contact sheet: 112, gendarmerie station, muhtars, operator's emergency team.

About Titan Savunma

Titan Savunma is an Ankara-based private security company licensed by the Ministry of Interior under Law No. 5188 and holding ISO 9001, 14001, 45001, 22301 and 28000 certificates. We work in English and Turkish with international energy investors and plan services for sites in different provinces through a single point of contact, written scope and regular reporting. Learn more about our energy generation and distribution security and critical infrastructure security services.

Sources and Further Reading

← Back to Security BulletinBack to Top
For Your Organisation

Let’s Discuss Your Security Needs

Tell us about your operations and expectations so we can define the appropriate service scope together.

Contact

Request a Security Proposal for Your Organisation

Tell us your facility type, location and general requirements. Together, we can define a service scope that suits your organisation.

Tell Us What You Need

Fields marked * are required.

What Happens Next

  1. Initial DiscussionWe respond within 15 minutes and clarify your requirements and facility details together.
  2. Service ScopeWe assess staffing needs and the working arrangements.
  3. ProposalWe prepare our proposal for the agreed service scope.

General Directorates

Ankara · Çankaya
İstanbul · Levent

Nine regional directorates · 81 provinces

Looking for a role? Visit our careers page